staub designlight ag offers no warranty and accepts no liability for damages caused by nonobservance of these instructions!
All staub designlight luminaires may only be operated with the
corresponding required power/voltage.
Before using a staub designlight luminaire with a screw attachment
for the first time, make sure that the front part of the light
is screwed tightly in place. Use the universal mounting key (see
accessories). Otherwise, the water-resistance of the luminaire is
not guaranteed.
Always switch off the power supply before opening a luminaire.
If the luminaire is wet, dry the light housing thoroughly.
Regarding halogen lights: never pour water over hot halogen
lights. The light glass may be destroyed due to the rapid change
in temperature. Never touch a halogen light that is switched
on or has not yet cooled down – danger of burns! When using
a staub designlight halogen luminaire above water, a safety
distance of at least 20 cm from flammable or heat-sensitive
materials must be ensured on all sides, as the temperature of the
luminaire housing can exceed 150°C. In flammable floors, walls,
ceilings, etc. (wood, plastic, etc.) only LED lights may be installed.
Only use the halogen bulbs specified by staub designlight ag.
Unsuitable bulbs may destroy the luminaire by generating too
much heat. Replace the sealing ring (O-ring) every time you replace
the bulb. It is essential that you follow the corresponding
operating instructions.
All staub designlight luminaires can be used indoors and outdoors,
above or under water. The corresponding restrictions are
listed on the relevant catalogue pages. All staub designlight
luminaires that are operated via a plug-in power supply unit may
only be used indoors.
The staub designlight spotlight, flat light, tube light as well
as the Ultraspot, Maxispot, Megaspot and Gigaspot, which
are not operated under water, must be mounted on the corresponding
luminaire holders to ensure adequate cooling!
All lights must not be covered with insulating materials such as
plastic, fabric, paper, etc. Fire hazard! The ambient temperature
must not exceed 40°C.
The iron-core and toroidal transformers (including connection
cables) are designed for outdoor use. Iron-core transformers
are waterproof against temporary immersion in accordance
with IP 67 (mains plug with IP 20). However, they must not be
placed in water. Toroidal transformers are only splash-proof in
accordance with IP 54. The connection cables must be protected
against martens. The connecting cable’s power plug must
be plugged into a water-protected socket which is protected by
a residual current circuit breaker (RCD). If no mains plug is required,
the mains connection (230 Volt AC) may only be established
by a trained and qualified electrician. All transformers must be
installed outside in a cement shaft or in the staub designlight
ground installation box in the ground with sufficient fresh air
supply (for cooling of the transformer/power supply unit). Regarding
the IP 67 iron-core transformer, any water penetrating the
shaft/box must be able to drain off immediately into the ground
(drainage bed). The IP 54 toroidal transformer must not come into
contact with running or standing water. All transformers must
not be installed in inflammable housings or niches (e.g. made
of wood). The local electrical installation regulations, especially
VDE 0100, SEV NIN 1000-1, 1995, must be observed. The input
and output circuits must be installed in accordance with local
installation regulations and routed in electrical conduits for protection.
All electrical cable connections must be grouted/sealed
to ensure that they are watertight.
All electrical cables that are laid in the ground must be routed
in electrical conduits for protection. All cables laid above ground
in outdoor areas to which animals have access (e.g. martens)
must be protected by means of a martens-resistant conduit.
All cable connections and electrical boxes must be professionally
waterproofed.
Damaged staub designlight products must be repaired immediately
via our customer service team, otherwise their waterresistance
and operational safety cannot be guaranteed.
All staub designlight LED lights may only be operated up to
a maximum ambient temperature of 40°C. The 230 V AC line
network must not transmit any impermissible peak voltages
(peak to peak) to the transformer/power supply unit, for example
during thunderstorms. On the 12/24 V side, the DC voltage must
not be exceeded (not even for a short time), otherwise the electronics
and/or the LED may be destroyed.
All staub designlight luminaires may only be operated with an
appropriate transformer/power supply unit and an upstream
residual current circuit breaker (RCD). For safety reasons, the
user must seek advice from an electrical specialist to determine
whether an RCD is already installed in the building.
All electrical installations with operating currents above 2 A or
operating voltages above 50 V AC or 120 V DC, which are newly
created or modified, may only be implemented by a specialist
with the appropriate installation permit.
All staub designlight luminaires that are used outdoors as
underwater lights and are approved for this purpose by staub
designlight ag must be removed from the water during the winter
season, unless they are installed at a depth of at least 30 cm,
because the glass spheres, glass bulbs and spotlight glass may
be destroyed in extreme cold conditions (ice).
All staub designlight luminaires/accessories which are used
under water must not come into contact with chlorine, hydrochloric
acid or other aggressive additives, which may cause the
surface of the stainless steel to oxidise or corrode. This does not
apply to the “Poolstar HP-LED” and “Megaspot Pool HP-LED”
underwater luminaires. These may be used in water containing the
usual chlorine levels that are permitted in swimming pool areas.
Other water additives (e.g. brine baths, etc.) must be tested
to check the resistance of the stainless steel before use and
approved in writing by staub designlight ag.
This website uses cookies to ensure the best experience possible. More information...